Abstract

The problem of the leakage flow between Guide Vane and the covering plate due to erosion is a strong source of inefficiency. To investigate this issue the TU university of Wien built a model, testing it at several configurations of Gap span and closing angle of the Guide Vane. This thesis aims to perform some simulations of these tests in ANSYS CFX, both in SS and Transient mode. The data are compared, the CFX model is validated and further considerations are carried out.

Item Type:Magistrali biennali
Corsi di Diploma di Laurea:Scuola di Ingegneria > Ingegneria Energetica
Scuola di Ingegneria > Ingegneria Energetica
Uncontrolled Keywords:guide, vane, clearance, gap, Francis, turbine
Subjects:Area 09 - Ingegneria industriale e dell'informazione > ING-IND/08 Macchine a fluido
Codice ID:56353
Relatore:Pavesi, Giorgio
Correlatore:Doujak, Eduard
Data della tesi:14 July 2017
Biblioteca:Polo di Ingegneria > Biblioteca Centrale di Ingegneria
Tipo di fruizione per il documento:on-line per i full-text
Tesi sperimentale (Si) o compilativa (No)?:Yes